For paired guide components, the running fit depends on the relationship between the bore and outside cylindrical surface. Mark the controlling datum and specify diameter tolerance, roughness and any required coaxiality.
A precision bore may need staged boring, grinding or finishing to meet the drawing. Material and heat treatment should be selected for the actual component.
Mark the Running Fit and Mounting Fit
Identify the guide length that slides through the mating bore and the part of the pillar that remains fixed in the tooling. Give the fit and roughness separately for each section where the dimensions differ.
Provide the mating bore dimensions and any datum-based alignment requirements. If an existing assembly is available, list the original dimensions separately from measured wear so the drawing remains the basis for the order.